CYS Series of Single Appropriate Emergency Lighting Power Supply
CYS series single phase EPS provided by Powerstar is specifically designed for the key loads like emergency lighting. CYS provide sine wave AC power for evacuation lights under emergency situation. In normal condition, power supply is switched to mains and at the same time charge the backup batteries intelligently. When the power supply goes blackout or the voltage is 25% over the normal voltage, reverse signal will be provided by the controller, and the reverse power resource will be activated and the device will switch to reverse resource output at the same time and it will continue to provide sine wave alternating current. When the electric supply back to normal, the emergency power resource will restore the power grid supply.
Application area:
It is ideal for important sites such as fire proctection, construction, financial places, medical places, military radars, vehicle mobile phones, anti-aircraft tunnels, underground equipments, supermarkets, shopping malls, schools, squares, railway stations, parks, stadiums and convention centers.
·Features
■Centralized power supply mode, which doesn’t need any special lights;
■Provide sine wave output with stabilized voltage and frequency without noise;
■Capable to be connected and monitored by computers and can be controlled by the fire protection center;
■LCD, LED display;
■Dual-line power supply can be switched automatically;
■Single chip design ensured the accuracy
■Simple design, convenient installation, low comprehensive cost and investment;
■Over 15 years’ service life and maintenance-free batteries (rechargeable 300-500 times) save your costs;
■Automatic switch;
■Wide application. It can provide emergent lighting for personnel evacuating, fire control and disaster rescue and other emergent situations;
Model
|
CYS-0.6KW
|
CYS-1KW
|
CYS-1.5KW
|
CYS-2KW
|
CYS-3KW
|
CYS-4KW
|
Power
|
0.6 KW
|
1.0 KW
|
1.5 KW
|
2.0 KW
|
3.0 KW
|
4.0 KW
|
Input
|
||||||
Voltage
|
Singlephase 220V±25%
|
|||||
Frequency
|
50Hz±5%
|
|||||
Output
|
||||||
Voltage
|
In emergency: 220V±3%
|
|||||
Frequency
|
In emergency 50Hz±0.5%
|
|||||
Waveform
|
Sine Wave
|
|||||
Battery
|
||||||
Type
|
Maintenance-free lead-acid batteries
|
|||||
Rated Voltage
|
DC36/90V
|
DC216V
|
||||
Standard Voltage |
48VDC
|
220VDC
|
||||
Charge Time
|
<20h
|
|||||
Charger
|
||||||
Voltage
|
42VDC
|
DC110VDC
|
DC258VDC
|
|||
Current
|
3A/5A
|
3A
|
||||
Method
|
Mean charging, float charging switch automatically
|
|||||
System
|
||||||
Transfer Time
|
<0.25s (adjustable to 0ms)
|
|||||
Emergency Time
|
90min (adjustable)
|
|||||
Overload
|
120% / 150% overloads can maintain 60 minutes / 5 seconds.
|
|||||
Protection
|
Under voltage, over current, short circuit protection
|
|||||
Output Loop Circuit
|
3 (standard type, according to the design requirements, to make the output loop)
|
|||||
Noise
|
In emergency <50dB (1m away)
|
|||||
Environment
|
||||||
Humidity
|
0~90% ( non-condensing)
|
|||||
Temperature
|
-25℃~40℃
|
|||||
Elevation
|
≤2500m
|
|||||
Adapted Loads
|
Applicable to all kinds of the lighting loads
|
|||||
Physical Feature
|
||||||
Size(mm)
(W*D*H)
|
600*220*1100
|
730*250*1200
|
750*410*1200
|
|||
Weight(kg)
Emergency Time (60/90min)
|
60/75
|
80/130
|
150/210
|
215/230
|
240/360
|
320/460
|
Model |
CYS-5KW |
CYS-6KW |
CYS-7KW |
CYS-8KW |
CYS-9KW |
CYS-10KW |
Power |
5.0 KW |
6.0 KW |
7.0 KW |
8.0 KW |
9.0 KW |
10 KW |
Input |
||||||
Voltage |
Single-phase 220V±25% |
Three-phase 380V±25%/ single-phase220V±25% |
||||
Frequency |
50Hz±5% |
|||||
Output |
||||||
Voltage |
Normal: same as the electric supply voltage In emergency:220V±3% |
|||||
Frequency |
Normal: same as the electric supply voltage In emergency:50Hz±0.5% |
|||||
Waveform |
Sine Wave |
|||||
Battery |
||||||
Type |
Maintenance-free lead-acid batteries |
|||||
Rated Voltage |
216VDC |
|||||
Standard Voltage |
220VDC |
|||||
Charge Time |
<20h |
|||||
Charger |
||||||
Voltage |
DC258V |
|||||
Current |
5A |
|||||
Method |
Mean charging, float charging switch automatically |
|||||
System |
||||||
Transfer Time |
<0.25s(adjustable to 0ms) |
|||||
Emergency Time |
90min(adjustable) |
|||||
Overload |
120%/150% overloads can maintain 60 minutes / 5 minutes |
|||||
Protection |
Under voltage, over current, short circuit protection |
|||||
Output Loop Circuit |
3(standard type, according to the design requirements) |
|||||
Noise |
Normal: no noise In emergency<50dB(1m away) |
|||||
Environment |
||||||
Humidity |
0~90% (non-condensing) |
|||||
Temperature |
-25℃~40℃ |
|||||
Elevation |
≤2500m |
|||||
Adapted Loads |
Applicable to all kinds of the lighting loads |
|||||
Physical Feature |
||||||
Installation Method |
Floor type |
|||||
Size(mm) (W*D*H)
|
750*410*1500 |
800*600*1800 |
800*600*2200 |
|||
Weight(kg) Emergency Time (60/90min) |
410/590 |
560/750 |
650/900 |
750/1000 |
850/1100 |
960/1200 |
Products shall be subject to any changes without additional notices. The pictures are for reference only. Please adhere to the original products in case of any mistake!